<  Solicite información sobre el producto de su interés

WhatsApp: 318 213 44 34

Ofertas

Grupo Alianza Estratégica GAE Ltda.

> Columnas HPLC  |  Fase Reversa, Interacción Hidrofílica y Fase Normal

<  Volver a: RPC NCP

HILICpak

Polymer-based Columns RPC (HILIC HILICpak)

VG-50

> Suitable for saccharides analysis by hydrophilic interaction chromatography (HILIC)

> High recovery ratio of reducing saccharides

> Polymer-based packing material provides excellent chemical stability and minimum deterioration over extended time period

> Easily regenerated by washing in a alkaline solution

> Also suitable for evaporative light scattering detector, corona charged aerosol detector, and LC/MS

VT-50

> Suitable for anionic substances analysis by hydrophilic interaction chromatography (HILIC)

> Depends on the eluent selected, the column adds ion exchange mode

> Polymer-based packing material provides excellent chemical stability and minimum deterioration over extended time period

> Suitable for LC/MS

New  VC-50

> Suitable for cationic substances including amines analysis by the carboxyl group

> Separation using mainly reversed phase mode or ion exchange mode other than HILIC mode depending on the substances

New  VN-50

> The diol group on the packing material is hydrophilic allowing HILIC mode to work

> Suitable for oligosaccharide separation which could not be separated by SEC mode columns or conventional HILIC columns

HILICpak VG-50 (Standard Columns) (Housing Material : SUS)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630200

HILICpak VG-50 4D

≥ 5,500

Amino

5

4.6 x 150

F7630100

HILICpak VG-50 4E

≥ 7,500

Amino

5

4.6 x 250

F6711100

HILICpak VG-50G 4A

Guard column

Amino

5

4.6 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VG-50 4D

10

0.5 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=20/80

VG-50 4E

15

0.5 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=20/80

VG-50G 4A

-

0.5 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=20/80

(Housing Material : PEEK)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630300

HILICpak VG-50 2D

≥ 3,500

Amino

5

2.0 x 150

F6711200

HILICpak VG-50G 2A

Guard column

Amino

5

2.0 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VG-50 2D

15

0.1 to 0.2

0.45

4 to 60

2 to 13

H2O/CH3CN=15/85

VG-50G 2A

-

0.1 to 0.2

0.45

4 to 60

2 to 13

H2O/CH3CN=15/85

Eluents :

Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.

HILICpak VT-50 (Standard Columns) (Housing Material: PEEK)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630400

HILICpak VT-50 2D

≥ 4,500

Quaternary ammonium

5

2.0 x 150

F6711300

HILICpak VT-50G 2A

Guard column

Quaternary ammonium

5

2.0 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VT-50 2D

10

0.2 to 0.3

0.5

4 to 60

2 to 13

25mM HCOONH4 aq.

/CH3CN=15/85

VT-50G 2A

-

0.2 to 0.3

0.5

4 to 60

2 to 13

25mM HCOONH4 aq.

/CH3CN=15/85

Eluents :

Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.

HILICpak VC-50 (Standard Columns) (Housing Material : PEEK)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630700

HILICpak VC-50 2D

≥ 3,500

Carboxyl

5

2.0 x 150

F6711600

HILICpak VC-50G 2A

Guard column

Carboxyl

5

2.0 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VC-50 2D

10

0.1 to 0.3

0.5

4 to 60

2 to 12

H2O

VC-50G 2A

-

0.1 to 0.3

0.5

4 to 60

2 to 12

H2O

Eluents :

Aqueous solutions of acetonitrile at any ratio, is used as eluent.*

Any salts soluble in the solution above are available.

* Methanol is not available as the eluent. Other organic solvents including methanol are not guaranteed as the eluent.

HILICpak VN-50 (Standard Columns) (Housing Material : PEEK)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630500

HILICpak VN-50 4D

≥ 10,000

Diol

5

4.6 x 150

F6711400

HILICpak VN-50G 2A

Guard column

Diol

5

4.6 x 10

F7630600

HILICpak VN-50 2D

≥ 3,500

Diol

5

2.0 x 150

F6711500

HILICpak VN-50G 2A

Guard column

Diol

5

2.0 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VN-50 4D

10

0.3 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=25/75

VN-50G 4A

-

0.3 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=25/75

VN-50 2D

10

0.05 to 0.3

0.5

4 to 60

2 to 13

H2O/CH3CN=25/75

VN-50G 2A

-

0.05 to 0.3

0.5

4 to 60

2 to 13

H2O/CH3CN=25/75

Eluents :

Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.

WhatsApp: 318 213 4434

Carrera 72C # 24-82  |  Modelia  |  Bogotá D.C.

Política integral de tratamiento de datos personales y comerciales

AVISO LEGAL: GRUPO ALIANZA ESTRATÉGICA GAE LTDA. es una empresa independiente y distribuidor autorizado exclusivo de SOTAX, YoungIn Chromass, IKA, CAMS, Shodex, Sciencix y QLA.

Para cualquier otra marca mencionada en este sitio, la compañía no es representante, distribuidor oficial ni afiliado. La mención de marcas de terceros y números de parte (OEM) se realiza exclusivamente con fines informativos para indicar compatibilidad, amparados en el derecho de uso referencial establecido en el Artículo 157 de la Decisión 486 de la CAN. Los productos ofrecidos son repuestos y consumibles compatibles, garantizando total transparencia al consumidor.