<  Solicite información sobre el producto de su interés

Celular  | WhatsApp: 318 213 44 34

Ofertas

Grupo Alianza Estratégica GAE Ltda.

> Columnas HPLC  |  Fase Reversa, Interacción Hidrofílica y Fase Normal

<  Volver a: RPC NCP

HILICpak

Polymer-based Columns RPC (HILIC HILICpak)

VG-50

> Suitable for saccharides analysis by hydrophilic interaction chromatography (HILIC)

> High recovery ratio of reducing saccharides

> Polymer-based packing material provides excellent chemical stability and minimum deterioration over extended time period

> Easily regenerated by washing in a alkaline solution

> Also suitable for evaporative light scattering detector, corona charged aerosol detector, and LC/MS

VT-50

> Suitable for anionic substances analysis by hydrophilic interaction chromatography (HILIC)

> Depends on the eluent selected, the column adds ion exchange mode

> Polymer-based packing material provides excellent chemical stability and minimum deterioration over extended time period

> Suitable for LC/MS

New  VC-50

> Suitable for cationic substances including amines analysis by the carboxyl group

> Separation using mainly reversed phase mode or ion exchange mode other than HILIC mode depending on the substances

New  VN-50

> The diol group on the packing material is hydrophilic allowing HILIC mode to work

> Suitable for oligosaccharide separation which could not be separated by SEC mode columns or conventional HILIC columns

HILICpak VG-50 (Standard Columns) (Housing Material : SUS)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630200

HILICpak VG-50 4D

≥ 5,500

Amino

5

4.6 x 150

F7630100

HILICpak VG-50 4E

≥ 7,500

Amino

5

4.6 x 250

F6711100

HILICpak VG-50G 4A

Guard column

Amino

5

4.6 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VG-50 4D

10

0.5 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=20/80

VG-50 4E

15

0.5 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=20/80

VG-50G 4A

-

0.5 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=20/80

(Housing Material : PEEK)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630300

HILICpak VG-50 2D

≥ 3,500

Amino

5

2.0 x 150

F6711200

HILICpak VG-50G 2A

Guard column

Amino

5

2.0 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VG-50 2D

15

0.1 to 0.2

0.45

4 to 60

2 to 13

H2O/CH3CN=15/85

VG-50G 2A

-

0.1 to 0.2

0.45

4 to 60

2 to 13

H2O/CH3CN=15/85

Eluents :

Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.

HILICpak VT-50 (Standard Columns) (Housing Material: PEEK)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630400

HILICpak VT-50 2D

≥ 4,500

Quaternary ammonium

5

2.0 x 150

F6711300

HILICpak VT-50G 2A

Guard column

Quaternary ammonium

5

2.0 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VT-50 2D

10

0.2 to 0.3

0.5

4 to 60

2 to 13

25mM HCOONH4 aq.

/CH3CN=15/85

VT-50G 2A

-

0.2 to 0.3

0.5

4 to 60

2 to 13

25mM HCOONH4 aq.

/CH3CN=15/85

Eluents :

Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.

HILICpak VC-50 (Standard Columns) (Housing Material : PEEK)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630700

HILICpak VC-50 2D

≥ 3,500

Carboxyl

5

2.0 x 150

F6711600

HILICpak VC-50G 2A

Guard column

Carboxyl

5

2.0 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VC-50 2D

10

0.1 to 0.3

0.5

4 to 60

2 to 12

H2O

VC-50G 2A

-

0.1 to 0.3

0.5

4 to 60

2 to 12

H2O

Eluents :

Aqueous solutions of acetonitrile at any ratio, is used as eluent.*

Any salts soluble in the solution above are available.

* Methanol is not available as the eluent. Other organic solvents including methanol are not guaranteed as the eluent.

HILICpak VN-50 (Standard Columns) (Housing Material : PEEK)

Product code

Product name

 Plate number

(TPN/column)

Functional

group

Particle size

(μm)

Size (mm)

I.D. x Length

F7630500

HILICpak VN-50 4D

≥ 10,000

Diol

5

4.6 x 150

F6711400

HILICpak VN-50G 2A

Guard column

Diol

5

4.6 x 10

F7630600

HILICpak VN-50 2D

≥ 3,500

Diol

5

2.0 x 150

F6711500

HILICpak VN-50G 2A

Guard column

Diol

5

2.0 x 10

Product name

Max. usable

pressure

(MPa)

Usual

flow rate

(mL/min)

Max.

usable

flow rate

(mL/min)

Usable temp.

range (°C)

Usable

pH range

Shipping solvent

VN-50 4D

10

0.3 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=25/75

VN-50G 4A

-

0.3 to 1.0

1.5

4 to 60

2 to 13

H2O/CH3CN=25/75

VN-50 2D

10

0.05 to 0.3

0.5

4 to 60

2 to 13

H2O/CH3CN=25/75

VN-50G 2A

-

0.05 to 0.3

0.5

4 to 60

2 to 13

H2O/CH3CN=25/75

Eluents :

Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.