> Suitable for saccharides analysis by hydrophilic interaction chromatography (HILIC)
> High recovery ratio of reducing saccharides
> Polymer-based packing material provides excellent chemical stability and minimum deterioration over extended time period
> Easily regenerated by washing in a alkaline solution
> Also suitable for evaporative light scattering detector, corona charged aerosol detector, and LC/MS
> Suitable for anionic substances analysis by hydrophilic interaction chromatography (HILIC)
> Depends on the eluent selected, the column adds ion exchange mode
> Polymer-based packing material provides excellent chemical stability and minimum deterioration over extended time period
> Suitable for LC/MS
> Suitable for cationic substances including amines analysis by the carboxyl group
> Separation using mainly reversed phase mode or ion exchange mode other than HILIC mode depending on the substances
> The diol group on the packing material is hydrophilic allowing HILIC mode to work
> Suitable for oligosaccharide separation which could not be separated by SEC mode columns or conventional HILIC columns
F7630200
HILICpak VG-50 4D
≥ 5,500
Amino
5
4.6 x 150
F7630100
HILICpak VG-50 4E
≥ 7,500
Amino
5
4.6 x 250
F6711100
HILICpak VG-50G 4A
Guard column
Amino
5
4.6 x 10
VG-50 4D
10
0.5 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=20/80
VG-50 4E
15
0.5 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=20/80
VG-50G 4A
-
0.5 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=20/80
F7630300
HILICpak VG-50 2D
≥ 3,500
Amino
5
2.0 x 150
F6711200
HILICpak VG-50G 2A
Guard column
Amino
5
2.0 x 10
VG-50 2D
15
0.1 to 0.2
0.45
4 to 60
2 to 13
H2O/CH3CN=15/85
VG-50G 2A
-
0.1 to 0.2
0.45
4 to 60
2 to 13
H2O/CH3CN=15/85
Eluents :
Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.
F7630400
HILICpak VT-50 2D
≥ 4,500
Quaternary ammonium
5
2.0 x 150
F6711300
HILICpak VT-50G 2A
Guard column
Quaternary ammonium
5
2.0 x 10
VT-50 2D
10
0.2 to 0.3
0.5
4 to 60
2 to 13
25mM HCOONH4 aq.
/CH3CN=15/85
VT-50G 2A
-
0.2 to 0.3
0.5
4 to 60
2 to 13
25mM HCOONH4 aq.
/CH3CN=15/85
Eluents :
Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.
F7630700
HILICpak VC-50 2D
≥ 3,500
Carboxyl
5
2.0 x 150
F6711600
HILICpak VC-50G 2A
Guard column
Carboxyl
5
2.0 x 10
VC-50 2D
10
0.1 to 0.3
0.5
4 to 60
2 to 12
H2O
VC-50G 2A
-
0.1 to 0.3
0.5
4 to 60
2 to 12
H2O
Eluents :
Aqueous solutions of acetonitrile at any ratio, is used as eluent.*
Any salts soluble in the solution above are available.
* Methanol is not available as the eluent. Other organic solvents including methanol are not guaranteed as the eluent.
F7630500
HILICpak VN-50 4D
≥ 10,000
Diol
5
4.6 x 150
F6711400
HILICpak VN-50G 2A
Guard column
Diol
5
4.6 x 10
F7630600
HILICpak VN-50 2D
≥ 3,500
Diol
5
2.0 x 150
F6711500
HILICpak VN-50G 2A
Guard column
Diol
5
2.0 x 10
VN-50 4D
10
0.3 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=25/75
VN-50G 4A
-
0.3 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=25/75
VN-50 2D
10
0.05 to 0.3
0.5
4 to 60
2 to 13
H2O/CH3CN=25/75
VN-50G 2A
-
0.05 to 0.3
0.5
4 to 60
2 to 13
H2O/CH3CN=25/75
Eluents :
Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.
AVISO LEGAL: GRUPO ALIANZA ESTRATÉGICA GAE LTDA. es una empresa independiente y distribuidor autorizado exclusivo de SOTAX, YoungIn Chromass, IKA, CAMS, Shodex, Sciencix y QLA.
Para cualquier otra marca mencionada en este sitio, la compañía no es representante, distribuidor oficial ni afiliado. La mención de marcas de terceros y números de parte (OEM) se realiza exclusivamente con fines informativos para indicar compatibilidad, amparados en el derecho de uso referencial establecido en el Artículo 157 de la Decisión 486 de la CAN. Los productos ofrecidos son repuestos y consumibles compatibles, garantizando total transparencia al consumidor.