> Suitable for saccharides analysis by hydrophilic interaction chromatography (HILIC)
> High recovery ratio of reducing saccharides
> Polymer-based packing material provides excellent chemical stability and minimum deterioration over extended time period
> Easily regenerated by washing in a alkaline solution
> Also suitable for evaporative light scattering detector, corona charged aerosol detector, and LC/MS
> Suitable for anionic substances analysis by hydrophilic interaction chromatography (HILIC)
> Depends on the eluent selected, the column adds ion exchange mode
> Polymer-based packing material provides excellent chemical stability and minimum deterioration over extended time period
> Suitable for LC/MS
> Suitable for cationic substances including amines analysis by the carboxyl group
> Separation using mainly reversed phase mode or ion exchange mode other than HILIC mode depending on the substances
> The diol group on the packing material is hydrophilic allowing HILIC mode to work
> Suitable for oligosaccharide separation which could not be separated by SEC mode columns or conventional HILIC columns
F7630200
HILICpak VG-50 4D
≥ 5,500
Amino
5
4.6 x 150
F7630100
HILICpak VG-50 4E
≥ 7,500
Amino
5
4.6 x 250
F6711100
HILICpak VG-50G 4A
Guard column
Amino
5
4.6 x 10
VG-50 4D
10
0.5 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=20/80
VG-50 4E
15
0.5 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=20/80
VG-50G 4A
-
0.5 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=20/80
F7630300
HILICpak VG-50 2D
≥ 3,500
Amino
5
2.0 x 150
F6711200
HILICpak VG-50G 2A
Guard column
Amino
5
2.0 x 10
VG-50 2D
15
0.1 to 0.2
0.45
4 to 60
2 to 13
H2O/CH3CN=15/85
VG-50G 2A
-
0.1 to 0.2
0.45
4 to 60
2 to 13
H2O/CH3CN=15/85
Eluents :
Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.
F7630400
HILICpak VT-50 2D
≥ 4,500
Quaternary ammonium
5
2.0 x 150
F6711300
HILICpak VT-50G 2A
Guard column
Quaternary ammonium
5
2.0 x 10
VT-50 2D
10
0.2 to 0.3
0.5
4 to 60
2 to 13
25mM HCOONH4 aq.
/CH3CN=15/85
VT-50G 2A
-
0.2 to 0.3
0.5
4 to 60
2 to 13
25mM HCOONH4 aq.
/CH3CN=15/85
Eluents :
Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.
F7630700
HILICpak VC-50 2D
≥ 3,500
Carboxyl
5
2.0 x 150
F6711600
HILICpak VC-50G 2A
Guard column
Carboxyl
5
2.0 x 10
VC-50 2D
10
0.1 to 0.3
0.5
4 to 60
2 to 12
H2O
VC-50G 2A
-
0.1 to 0.3
0.5
4 to 60
2 to 12
H2O
Eluents :
Aqueous solutions of acetonitrile at any ratio, is used as eluent.*
Any salts soluble in the solution above are available.
* Methanol is not available as the eluent. Other organic solvents including methanol are not guaranteed as the eluent.
F7630500
HILICpak VN-50 4D
≥ 10,000
Diol
5
4.6 x 150
F6711400
HILICpak VN-50G 2A
Guard column
Diol
5
4.6 x 10
F7630600
HILICpak VN-50 2D
≥ 3,500
Diol
5
2.0 x 150
F6711500
HILICpak VN-50G 2A
Guard column
Diol
5
2.0 x 10
VN-50 4D
10
0.3 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=25/75
VN-50G 4A
-
0.3 to 1.0
1.5
4 to 60
2 to 13
H2O/CH3CN=25/75
VN-50 2D
10
0.05 to 0.3
0.5
4 to 60
2 to 13
H2O/CH3CN=25/75
VN-50G 2A
-
0.05 to 0.3
0.5
4 to 60
2 to 13
H2O/CH3CN=25/75
Eluents :
Aqueous solutions of acetonitrile (or Methanol) at any ratio, is used as eluent. Any salts soluble in the solution above are available.