<  Solicite información sobre el producto de su interés

Celular  | WhatsApp: 318 213 44 34

Ofertas

Grupo Alianza Estratégica GAE Ltda.

> Columnas HPLC  |  Exclusión por Tamaño

<  Volver a: Organic SEC

Linear Calibration Type

Organic SEC (GPC) columns

LF

> Employs a special packing material with a wide pore size distribution (multi pore type)

> Highly linear calibration curve without inflection points

> Molecular weight distribution can be determined with high precision

> Enables analysis over a broad range of molecular weights

> Column for rapid analysis (LF-604) and column for high performance analysis (LF-404) enabling reduction in solvent use are also available

> Corresponds to USP L21

Please refer to Replacement of In-Column Solvent

*Use of the LF-604 and the LF-404 with semi-micro type devices is recommended.

(Standard column) shipping solvent : Tetrahydrofulan (THF)

Product code

F6021041

F6709621

Product name

GPC LF-804

GPC LF-G

 Plate number

(TPN/column)

≥ 17,000

Guard column

Particle size

(μm)

6

6

Size (mm)

I.D. x Length

8.0 x 300

4.6 x 10

Product name

LF-804

LF-G

Max. usable

pressure

(MPa)

3.5

-

Recommended

flow rate

(mL/min)

1.0

-

Max. usable

flow rate

(mL/min)

2.0

-

Max usable

temp. (°C)

20 to 60

20 to 60

(Standard column) shipping solvent : Tetrahydrofulan (THF)

Product code

F6021042

F6709621

Product name

GPC LF-604

GPC LF-G

 Plate number

(TPN/column)

≥ 9,000

Guard column

Particle size

(μm)

6

6

Size (mm)

I.D. x Length

6.0 x 150

4.6 x 10

Product name

LF-604

LF-G

Max. usable

pressure

(MPa)

3.5

-

Recommended

flow rate

(mL/min)

0.5

-

Max. usable

flow rate

(mL/min)

1.0

-

Max usable

temp. (°C)

20 to 60

20 to 60

(High-perfomance semi-micro column) shipping solvent : Tetrahydrofulan (THF)

Product code

F6021043

F6709621

Product name

GPC LF-404

GPC LF-G

 Plate number

(TPN/column)

≥ 14,000

Guard column

Particle size

(μm)

6

6

Size (mm)

I.D. x Length

4.0 x 250

4.6 x 10

Product name

LF-404

LF-G

Max. usable

pressure

(MPa)

3.5

-

Recommended

flow rate

(mL/min)

0.3

-

Max. usable

flow rate

(mL/min)

0.6

-

Max usable

temp. (°C)

20 to 60

20 to 60

[Target molecular weight range and Exclusion limit]

* Please use the above table as a rough indication for the column selection.

With Polystyrene (eluent : THF)

Product name

Target molecular weight range

Exclusion limit

LF-804

300 - 2,000,000

2,000,000

LF-604

300 - 2,000,000

2,000,000

LF-404

300 - 2,000,000

2,000,000

Celular | WhatsApp: 318 213 4434

Calle 35A sur No. 26B 67  |  Barrio Bravo Páez, Bogotá D.C.  |  Colombia

Política de manejo de información (PDF)