> Polymer-based SEC columns exhibit high solvent durability
> Supports both aqueous and organic solvents
F7600000
F7600001
F7600002
F7600003
F7600004
F6710018
Asahipak GF-210 HQ
Asahipak GF-310 HQ
Asahipak GF-510 HQ
Asahipak GF-710 HQ
Asahipak GF-7M HQ
Asahipak GF-1G 7B
≥ 19,000
≥ 19,000
≥ 19,000
≥ 11,000
≥ 13,000
Guard column
5
5
5
9
9
9
7.5 x 300
7.5 x 300
7.5 x 300
7.5 x 300
7.5 x 300
7.5 x 50
H2O
CH3OH/H2O=30/70
CH3OH/H2O=30/70
CH3OH/H2O=30/70
CH3OH/H2O=30/70
CH3OH/H2O=30/70
F7600100
F7600110
F7600024
F7600120
MSpak GF-310 4B
MSpak GF-310 4D
MSpak GF-310 4E
MSpak GF-310 2D
≥ 3,000
≥ 10,000
≥ 16,000
≥ 5,500
5
5
5
5
4.6 x 50
4.6 x 150
4.6 x 250
2.0 x 150
H2O
H2O
H2O
H2O
GF-210 HQ
GF-310 HQ
GF-510 HQ
GF-710 HQ
GF-7M HQ
GF-1G 7B
9.0
7.0
6.5
2.5
4.5
-
0.4 to 0.6
0.4 to 0.6
0.4 to 0.6
0.4 to 0.6
0.4 to 0.6
-
1.0
1.0
1.0
1.0
1.0
-
4 to 60
4 to 60
4 to 60
4 to 60
4 to 60
4 to 60
2 to 9
2 to 9
2 to 9
2 to 9
2 to 9
2 to 9
GF-310 4B
GF-310 4D
GF-310 4E
GF-310 2D
2.0
4.0
6.0
6.0
-
-
-
-
0.6
0.5
0.5
0.2
10 to 60
10 to 60
10 to 60
10 to 60
2 to 9
2 to 9
2 to 9
2 to 9
Water with salt
Yes
Yes
DMF
Yes
Yes
Methanol
Yes
Yes
Acetone
Yes
Yes
Ethanol
Yes
Yes
Chloroform
Yes*
Yes
Acetonitrile
Yes*
Yes
Ethyl acetate
Yes*
Yes
THF
Yes
Yes
DMSO
Yes*
0 to 50% Yes
* When replacing acetonitrile, ethyl acetate or chloroform with water, replace with methanol first and then replace with water.
* When replacing water with ethyl acetate or chloroform, replace with methanol first and then replace with the required eluent condition.
F7600200
F7600201
F7760512
F7760511
F7760712
Asahipak GF-210 4D
Asahipak GF-210 4E
GF510A-4D
GF510A-4E
GF710A-4D
5
5
5
5
9
4.6 x 150
4.6 x 250
4.6 x 150
4.6 x 250
4.6 x 150
GF-210 HQ
GF-210 HQ
GF-510 HQ
GF-510 HQ
GF-710 HQ
F6810030
F6810031
F6810032
F6810033
F6810038
F6810039
F6810040
F6810041
F6710020
Asahipak GS-310 20F
Asahipak GS-510 20F
Asahipak GS-710 20F
Asahipak GSM-700 20F
Asahipak GS-310 20G
Asahipak GS-510 20G
Asahipak GS-710 20G
Asahipak GSM-700 20G
Asahipak GS-10G 7B
≥ 8,000
≥ 8,000
≥ 8,000
≥ 8,000
≥ 14,000
≥ 14,000
≥ 14,000
≥ 14,000
Guard column
13
13
13
13
13
13
13
13
20
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 500
20.0 x 500
20.0 x 500
20.0 x 500
7.5 x 50
GS-310 20F
GS-510 20F
GS-710 20F
GSM-700 20F
GS-310 20G
GS-510 20G
GS-710 20G
GSM-700 20G
GS-10G 7B
5 to 8
5 to 8
2 to 3
2 to 3
5 to 8
5 to 8
2 to 3
2 to 3
-
5 to 8
5 to 8
2 to 3
2 to 3
5 to 8
5 to 8
2 to 3
2 to 3
-
GF-310 HQ
GF-510 HQ
GF-710 HQ
GF-7M HQ
GF-310 HQ
GF-510 HQ
GF-710 HQ
GF-7M HQ
Guard column
(Note)
The usable solvents for preparative columns of GF-710 HQ, GS-710 20F and 20G, are water and methanol. GSM-700 20F or 20G is recommended when other solvents are required.
[Target molecular weight range and Exclusion limit]
* Please use the above table as a rough indication for the column selection.
GF-210
GF-310
GF-510
GF-710
GF-7M
*( ) Estimated value
300 - 4,000
300 - 30,000
5,000 - 200,000
100,000 - *(10,000,000)
300 - *(10,000,000)
9,000
40,000
300,000
1,000,000
*(10,000,000)
*(10,000,000)
GF-210
GF-310
GF-510
GF-710
GF-7M
100 - 2,000
200 - 4,000
2,000 - 200,000
20,000 - **(10,000,000)
200 - **(10,000,000)
*PEG : polyethylene glycol *PEO : polyethylene oxide **( ) Estimated value
AVISO LEGAL: GRUPO ALIANZA ESTRATÉGICA GAE LTDA. es una empresa independiente y distribuidor autorizado exclusivo de SOTAX, YoungIn Chromass, IKA, CAMS, Shodex, Sciencix y QLA.
Para cualquier otra marca mencionada en este sitio, la compañía no es representante, distribuidor oficial ni afiliado. La mención de marcas de terceros y números de parte (OEM) se realiza exclusivamente con fines informativos para indicar compatibilidad, amparados en el derecho de uso referencial establecido en el Artículo 157 de la Decisión 486 de la CAN. Los productos ofrecidos son repuestos y consumibles compatibles, garantizando total transparencia al consumidor.