Grupo Alianza Estratégica GAE Ltda.

> Columnas HPLC  |  Exclusión por Tamaño

<  Volver a: Organic SEC

General Analysis

Organic SEC (GPC) General Analysis

KF-800

K-800

KD-800

> Standard organic solvent SEC (GPC) column

> Supports a wide range of applications from low to high molecular weight compounds

> Corresponds to USP L21

* Please refer to Replacement of In-Column Solvent

* Please refet to Solvent-peak Separation Columns for Organic SEC (GPC)

* The columns with ‘L’ or ‘M’ at the end of column names are mixed-gel column capable of analyzing samples over a wide range of molecular weight distribution.

(Standard Columns) KF-800 series shipping solvent : Tetrahydrofuran (THF)

Product code

Product name

 Plate number

(TPN/column)

Particle size

(μm)

Size (mm)

I.D. x Length

F6028010

F6028020

F6028025

F6028030

F6027030

F6028040

F6027040

F6028050

F6027050

F6028060

F6028090

F6027060

F6028070

F6027070

F6700300

GPC KF-801

GPC KF-802

GPC KF-802.5

GPC KF-803

GPC KF-803L

GPC KF-804

GPC KF-804L

GPC KF-805

GPC KF-805L

GPC KF-806

GPC KF-806M

GPC KF-806L

GPC KF-807

GPC KF-807L

GPC KF-G 4A

(GPC KF-G)

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 11,000

  ≥ 11,000

  ≥ 11,000

  ≥ 13,000

  ≥ 11,000

  ≥ 6,000

  ≥ 6,000

Guard column

6

6

6

6

6

7

7

10

10

10

10

10

18

18

8

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

4.6 x 10

F6709350

GPC KF-800D

Solvent-peak separation column

10

8.0 x 100

For all products

Recommended flow rate: 0.5 to 1.0mL/min

Max. usable flow rate: 2.0mL/min

Max. usable pressure: 3.5 MPa

Max. usable temperature: 60°C

 

[Target molecular weight range and Exclusion limit]

* Please use the above table as a rough indication for the column selection.

With Polystyrene (eluent: THF)

Product name

KF-801

KF-802

KF-802.5

KF-803

KF-803L

KF-804

KF-804L

KF-805

KF-805L

KF-806

KF-806M

KF-806L

KF-807

KF-807L

*( ) Estimated value

Target molecular weight range

100 - 700

300 - 3,000

300 - 8,000

1,000 - 50,000

100 - 50,000

7,000 - 300,000

100 - 300,000

50,000 - 2,000,000

300 - 2,000,000

150,000 - *(20,000,000)

1,000 - *(20,000,000)

300 - *(20,000,000)

300,000 - *(200,000,000)

300 - *(200,000,000)

Exclusion limit

1,500

5,000

20,000

70,000

70,000

400,000

400,000

4,000,000

4,000,000

*(20,000,000)

*(20,000,000)

*(20,000,000)

*(200,000,000)

*(200,000,000)

K-800 series shipping solvent : Chloroform

Product code

Product name

 Plate number

(TPN/column)

Particle size

(μm)

Size (mm)

I.D. x Length

F6028110

F6028120

F6028125

F6028130

F6028194

F6028140

F6028195

F6028150

F6028196

F6028160

F6028190

F6028197

F6028170

F6028198

F6700401

GPC K-801

GPC K-802

GPC K-802.5

GPC K-803

GPC K-803L

GPC K-804

GPC K-804L

GPC K-805

GPC K-805L

GPC K-806

GPC K-806M

GPC K-806L

GPC K-807

GPC K-807L

GPC K-G 4A

(GPC K-G)

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 18,000

  ≥ 11,000

  ≥ 11,000

  ≥ 11,000

  ≥ 13,000

  ≥ 11,000

  ≥ 6,000

  ≥ 6,000

Guard column

 

6

6

6

6

6

7

7

10

10

10

10

10

18

18

8

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

4.6 x 10

F6709450

GPC K-800D

Solvent-peak separation column

10

8.0 x 100

For all products

Recommended flow rate: 0.5 to 1.0mL/min

Max. usable flow rate: 2.0mL/min

Max. usable pressure: 3.5 MPa

Max. usable temperature: 60°C

 

[Target molecular weight range and Exclusion limit]

* Please use the above table as a rough indication for the column selection.

With Polystyrene (eluent : Chloroform)

Product name

K-801

K-802

K-802.5

K-803

K-803L

K-804

K-804L

K-805

K-805L

K-806

K-806M

K-806L

K-807

K-807L

*( ) Estimated value

Target molecular weight range

100 - 700

300 - 3,000

300 - 8,000

1,000 - 50,000

100 - 50,000

7,000 - 300,000

100 - 300,000

50,000 - 2,000,000

300 - 2,000,000

150,000 - *(20,000,000)

1,000 - *(20,000,000)

300 - *(20,000,000)

300,000 - *(200,000,000)

300 - *(200,000,000)

Exclusion limit

1,500

5,000

20,000

70,000

70,000

400,000

400,000

4,000,000

4,000,000

*(20,000,000)

*(20,000,000)

*(20,000,000)

*(200,000,000)

*(200,000,000)

KD-800 series shipping solvent : Dimethylformamide (DMF)

Product code

Product name

 Plate number

(TPN/column)

Particle size

(μm)

Size (mm)

I.D. x Length

F6028210

F6028220

F6028225

F6028230

F6028240

F6028250

F6028260

F6028290

F6028270

F6700411

GPC KD-801

GPC KD-802

GPC KD-802.5

GPC KD-803

GPC KD-804

GPC KD-805

GPC KD-806

GPC KD-806M

GPC KD-807

GPC KD-G 4A

(GPC KD-G)

  ≥ 17,000

  ≥ 17,000

  ≥ 17,000

  ≥ 17,000

  ≥ 17,000

  ≥ 11,000

  ≥ 11,000

  ≥ 13,000

  ≥ 6,000

Guard column

6

6

6

6

7

10

10

10

18

8

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

8.0 x 300

4.6 x 10

For all products

Recommended flow rate: 0.5 to 1.0mL/min

Max. usable flow rate: 1.5mL/min

Max. usable pressure: 3.5 MPa

Max. usable temperature: 60°C

 

[Target molecular weight range and Exclusion limit]

* Please use the above table as a rough indication for the column selection.

With *PEG/PEO (eluent : DMF)

Product name

Target molecular weight range

KD-801

KD-802

KD-802.5

KD-803

KD-804

KD-805

KD-806

KD-806M

KD-807

100 - 1,500

200 - 4,000

400 - 10,000

1,000 - 50,000

4,000 - 200,000

30,000 - **(4,000,000)

30,000 - **(40,000,000)

1,000 - **(40,000,000)

50,000 - **(200,000,000)

*PEG : polyethylene glycol *PEO : polyethylene oxide  **( ) Estimated value

Exclusion limit

2,500

7,000

20,000

70,000

200,000

**(4,000,000)

**(40,000,000)

**(40,000,000)

**(200,000,000)

< Volver

<  Solicite información sobre el producto de su interés

Celular  | WhatsApp: 318 213 44 34

Ofertas

Celular | WhatsApp: 318 213 4434

Calle 35A sur No. 26B 67  |  Barrio Bravo Páez, Bogotá D.C.  |  Colombia

Política de manejo de información (PDF)