> Polymer-based packed columns for aqueous SEC (GFC) analysis
> Supports a wide range of molecular weight sample analysis
> The eluent can be replaced with DMF (except SB-802 HQ and SB-807 HQ), enabling the analysis of polar polymers
> Method using SB-804 HQ or SB-805 HQ for gelatin’s mean molecular weight determination is comparable with PAGI method (Ver. 10, Japan)
> Corresponds to USP L38、L39
> SB-802 HQ corresponds to USP L25
> SB-802.5 HQ corresponds to USP L25
> SB-803 HQ corresponds to USP L37
> Column for the analysis of water-soluble ultra high molecular weight polymers
> Large particle size gel is packed to prevent shear degradation of polymers
> Corresponds to USP L38 and L39
F6429100
F6429101
F6429102
F6429103
F6429104
F6429105
F6429106
F6709430
OHpak SB-802 HQ
OHpak SB-802.5 HQ
OHpak SB-803 HQ
OHpak SB-804 HQ
OHpak SB-805 HQ
OHpak SB-806 HQ
OHpak SB-806M HQ
OHpak SB-G 6B
(OHpak SB-G)
≥ 12,000
≥ 16,000
≥ 16,000
≥ 16,000
≥ 12,000
≥ 12,000
≥ 12,000
Guard column
8
6
6
10
13
13
13
10
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
6.0 x 50
0.02% NaN3 aq.
0.02% NaN3 aq.
0.02% NaN3 aq.
0.02% NaN3 aq.
0.02% NaN3 aq.
0.02% NaN3 aq.
0.02% NaN3 aq.
0.02% NaN3 aq.
SB-802 HQ
SB-802.5 HQ
SB-803 HQ
SB-804 HQ
SB-805 HQ
SB-806 HQ
SB-806M HQ
SB-G 6B
0
100
100
75
75
75
75
75
0
75
75
75
75
75
75
75
0
100
100
100
100
100
100
100
5.0
5.0
5.0
3.0
3.0
3.0
3.0
-
*( ): Estimated value
CH3OH: Methanol, CH3CN: Acetonitrile, DMF: Dimethyformamide
1.2
1.2
1.2
1.2
1.2
1.2
1.2
-
70
70
70
70
70
70
70
70
3 to 10
3 to 10
3 to 10
3 to 10
3 to 10
3 to 10
3 to 10
3 to 10
F6429108
F6709431
OHpak SB-807 HQ
OHpak SB-807G
≥ 1,500
Guard column
35
35
8.0 x 300
8.0 x 50
H2O
H2O
SB-807 HQ
SB-807G
30
30
30
30
0
0
CH3OH: Methanol, CH3CN: Acetonitrile, DMF: Dimethyformamide
0.5
-
1.5
-
60
60
3 to 10
3 to 10
F6516011
F6516012
F6516013
F6516014
F6516015
F6516016
F6516017
F6709555
OHpak SB-2002
OHpak SB-2002.5
OHpak SB-2003
OHpak SB-2004
OHpak SB-2005
OHpak SB-2006
OHpak SB-2006M
OHpak SB-G 8B
(OHpak SB-LG)
≥ 9,000
≥ 12,000
≥ 12,000
≥ 12,000
≥ 12,000
≥ 12,000
≥ 12,000
Guard column
15
10
10
18
20
20
20
18
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
8.0 x 50
SB-802 HQ
SB-802.5 HQ
SB-803 HQ
SB-804 HQ
SB-805 HQ
SB-806 HQ
SB-806M HQ
Guard column
For all products
Max. usable flow rate: 5.0mL/min
Max. usable pressure: 2.0 MPa
Max. usable temperature: 60°C
(Note)
The maximum solvent tolerance of the SB-2000 series for methanol, acetonitrile, and DMF is 50%. Solvent tolerance differs from that of the standard SB-800 HQ columns.
[Target molecular weight range and Exclusion limit]
* Please use the above table as a rough indication for the column selection.
SB-802 HQ
SB-802.5 HQ
SB-803 HQ
SB-804 HQ
SB-805 HQ
SB-806 HQ
SB-806M HQ
SB-807 HQ
*( ) Estimated value
200 - 1,000
500 - 10,000
1,000 - 100,000
5,000 - 400,000
100,000 - 1,000,000
100,000 - *(20,000,000)
500 - *(20,000,000)
500,000 - *(500,000,000)
1,000
10,000
100,000
1,000,000
*(4,000,000)
*(20,000,000)
*(20,000,000)
*(500,000,000)
SB-802.5 HQ
SB-803 HQ
SB-804 HQ
SB-805 HQ
SB-806 HQ
SB-806M HQ
100 - 2,000
200 - 40,000
500 - 300,000
50,000 - 700,000
70,000 - **(20,000,000)
200 - **(20,000,000)
*PEG : polyethylene glycol *PEO : polyethylene oxide **( ) Estimated value
AVISO LEGAL: GRUPO ALIANZA ESTRATÉGICA GAE LTDA. es una empresa independiente y distribuidor autorizado exclusivo de SOTAX, YoungIn Chromass, IKA, CAMS, Shodex, Sciencix y QLA.
Para cualquier otra marca mencionada en este sitio, la compañía no es representante, distribuidor oficial ni afiliado. La mención de marcas de terceros y números de parte (OEM) se realiza exclusivamente con fines informativos para indicar compatibilidad, amparados en el derecho de uso referencial establecido en el Artículo 157 de la Decisión 486 de la CAN. Los productos ofrecidos son repuestos y consumibles compatibles, garantizando total transparencia al consumidor.